Blower Maintenance Checklist for Continuous Duty

By Sigma Engineering Team2 October 20265 min read

A Roots blower on round-the-clock aeration runs about 8,700 hours a year. Most failures we see on site start with something small that was missed for a few months.

Daily

  • Note discharge pressure and motor current, and compare them with the commissioning values
  • Listen for new knocking or rubbing noise
  • Check the oil level in the gear end and drive end sight glasses
  • Look for oil leaks at the shaft seals

Weekly

  • Clean or check the inlet filter, more often on dusty sites
  • Check belt tension and condition
  • Confirm the safety valve is free and not passing air

Monthly

  • Check foundation bolts and anti-vibration mounts
  • Inspect the non-return valve and flexible connectors
  • Record bearing temperatures

At the oil change interval

  • Change the gear oil with the grade the manufacturer specifies
  • Inspect belts and pulleys for wear
  • Check timing gear backlash if noise has gone up

Rule of thumb

A rise in motor current at the same pressure usually means a choked filter or fouled diffusers, not a blower fault.

Keep the standby in rotation

Run the duty and standby units in turn, for example weekly. Both stay healthy and you know the standby will start when you need it.

Conclusion

Our AMC visits follow this checklist and keep a record of the readings, so trends show up well before a breakdown.

Talk to an engineer+91 94870 69937
Request a QuoteDownload Catalogue

Related guides

BlowersRoots vs Twin Lobe vs Tri Lobe: Which to Choose?STPHow to Select the Right Roots Blower for Aeration in STPsPumpsMultistage vs Centrifugal Pumps
Get a Quote

Tell us your process. We'll size the right equipment.

Share your flow rate, pressure, fluid or existing equipment details and our team will recommend a suitable solution.

Request a QuoteDownload Brochure
Call us+91 94870 69937Email ussales@sigmaprocesscontrols.comLocationsCoimbatore · Navi Mumbai