Blog/STP

How to Select the Right Roots Blower for Aeration in STPs

By Sigma Engineering Team10 October 20267 min read

Aeration is the largest energy consumer in a sewage treatment plant. Choosing a blower on air volume alone leads to overload, heat and short bearing life. Here is how we size one against real operating conditions.

1. Start with oxygen demand

Work back from the BOD/COD load to the oxygen requirement, then convert to air flow using diffuser efficiency and submergence depth. Express the result in m³/hr or CFM at site conditions, not at standard conditions.

2. Calculate discharge pressure

Add tank water depth, diffuser head loss, piping and valve losses, and a margin for diffuser fouling. Most STP aeration tanks land between 0.4 and 0.7 kg/cm², which suits Roots and tri-lobe blowers.

Rule of thumb

Size for the hottest day and the dirtiest diffuser, not the commissioning day.

3. Choose the blower type

  • Twin-lobe Roots: proven, robust, easy to maintain for continuous duty.
  • Tri-lobe: lower pulsation and noise, better efficiency at higher pressures.
  • Ring blowers: suited to small tanks and low flow, oil-free.

4. Plan for motor, drive and spares

Select motor HP with at least 10% margin, specify a VFD for load variation, and keep a standby blower on duty rotation. An AMC covering belts, oil, filters and bearings keeps the plant compliant between shutdowns.

5. Worked example: 500 KLD STP

A typical 500 KLD plant with 4 m side water depth needs roughly the following. Treat these as starting points and confirm against your actual BOD load.

ParameterValueNote
Air flow~600 m³/hrPer duty blower, site conditions
Discharge pressure0.55 kg/cm²Includes diffuser fouling margin
Motor15 HPWith 10% margin and VFD
Configuration1 duty + 1 standbyRotate weekly

Common sizing mistakes

  • Using standard-condition air flow instead of site temperature and altitude.
  • Ignoring pressure drop in long headers, silencers and non-return valves.
  • Oversizing the motor, then running at low load with poor efficiency.
  • No standby unit, so maintenance forces a plant shutdown.

Frequently asked questions

Roots or tri-lobe for aeration?

Roots suits most STPs on cost and serviceability. Choose tri-lobe where noise, pulsation or energy cost matter most.

How often should a blower be serviced?

Check oil and belts monthly, change filters every quarter and inspect bearings annually. An AMC schedules all of this.

Can Sigma size the blower for me?

Yes. Send your flow, pressure and tank details through the form and our engineers will recommend a model.

Conclusion

A correctly sized blower runs cooler, uses less power and lasts longer. Start from oxygen demand, calculate real discharge pressure, then choose the type, drive and spares to match. If you would like a second opinion, our team reviews applications free of charge.

Talk to an engineer+91 94870 69937
Request a QuoteDownload Catalogue

Related guides

BlowersRoots vs Twin Lobe vs Tri Lobe: Which to Choose?PumpsMultistage vs Centrifugal PumpsMaintenanceBlower Maintenance Checklist for Continuous Duty
Get a Quote

Tell us your process. We'll size the right equipment.

Share your flow rate, pressure, fluid or existing equipment details and our team will recommend a suitable solution.

Request a QuoteDownload Brochure
Call us+91 94870 69937Email ussales@sigmaprocesscontrols.comLocationsCoimbatore · Navi Mumbai